Product Description
Preformance Characteristics:
1) DSP digital control technology
Core system uses the world's most advanced all-digital DSP control technology, which can effectively guarantee the UPS' core system accurate, and fast running.
2) Advanced IGBT inverter technology
Combined high-reliable and high-efficiency IGBT inverter technology with high-frequency Pulse Width Modulation technology (PWM).
It could reduce noise and power loss, to ensure users can load in a variety of working situations and obtain high-quality voltage output and maximum cost-effectiveness, but also make input efficiency more than 95%.
3) Pure-online double conversion technology
Reliable and stable, after filtered and regulated, the output sine wave from pure-online double conversion technology, not only has the atmospheric disturbance suppression filter, but also with the standard output isolation transformers, static bypass, maintenance bypass, make this product with higher ability to engage in short circuit current. And it can be applied to the worst working environment.
4) Perfect protection
Perfectly system protection functions: It has AC over-voltage, under-voltage, output over-voltage, under-voltage, output overload, short circuit protection, inverter, rectifier over-temperature protection, voltage under-voltage warning, battery over charging protection and other protections in one to ensure the system to operate stably and reliably.
5) Powerful Redundant Parallel Connection Function
Durable and reliable design of industrial-type modular structure, combined with full digital DSP control technology core system, make this product not only can be used for N +1 / N + X redundancy and the ability of enlarge the capacity, but also permit different power and different times of the UPS could be in parallel. It greatly reduced the user's pre-and post-purchasing costs, and increased capacity costs, but also expanded upper spaces of increasing capacity.
6) Powerful communication system
The standard equipped with RS232 interface, do contact relays, emergency switching device EPO input interface.
7) Low-power dissipation but high-efficiency
To achieve more than 98% of ultra-high efficiency under ECO economic model, which can effectively bring down the amount of electricity, and effective in accordance with the requirements of energy-saving target of the country.
8) Prediction warning system
LCD panel automatic detection function and timely warning in advance, with the boot self-diagnosis function. It could avoid the hidden danger in time due to UPS' failure, which caused risks. Also it could automatically alarm by setting the battery discharge to standby time is less than a set value.
9) Humanized panel display
Humanized panel settings, the users can set system parameters, date, output voltage, battery capacity, alarm function, light-load shutdown, system boot time, MODEM settings, such as orders, also it can be up to 120 abnormal failure information for users to query.
10) Super-strong environment adaptability
This product has superior environmental adaptability, wide AC input range, greatly reduces the frequency of battery using, and effectively extends the battery life.
11) Powerful Overload Ability
Using the pure-online double conversion technology, with the output isolation transformers, static bypass, and maintenance bypass.
Inverter Overload Ability reached 110% / 125% / 150% overloading time can last for 300min/10min/1min.
Bypass Overload Ability reached 150% / 170% / 250% overloading time can last for 60min/10min/1min.
PLTD Online Low-frequency UPS Three-phases in & output 10KVA---300KVA |
Input circuit Rectifier |
Model | 10KL | 20KL | 30KL | 40KL | 50KL | 60KL | 80KL | 100KL | 120KL | 150KL | 200KL | 250KL | 300KL | 400KL |
Rating capacity in KVA | 10 | 20 | 30 | 40 | 50 | 60 | 80 | 100 | 120 | 150 | 200 | 250 | 300 | 400 |
Maximum input current per phase (A) | 25 | 50 | 75 | 105 | 125 | 150 | 199 | 240 | 300 | 375 | 480 | 600 | 750 | 960 |
Performance and Principle | Online supplying power,static bypass(uninterruptible transfer),Dual conversion, full-isolated output AC |
Phase | Tri-phasic (Line)+N+G |
Input volt. | 380VAC±25% |
Input frequency | 50Hz±10%(60HZ±10%) |
THD | <10% |
Soft-start | 0~100% 5 Sec |
Input P. F. | ≥0.9 |
Output circuit Rectifier |
Maximum output DC volt. | 432VDC |
CPU configuration of charge current | 6~20A(adjustable) |
Battery |
Maximum discharge current(A) | 28 | 56 | 85 | 113 | 141 | 169 | 225 | 282 | 338 | 423 | 564 | 700 | 840 | 1128 |
Quantity | 32 cells |
Rating battery DC volt. | 384VDC |
Float-charge Volt. | 432VDC |
Charge current | 6A~20A(adjustable) |
Type | Sealed Value-regulated Lead-acid battery |
Service time | Battery serve more than 5-Yrs when float-charge status. |
Inverter |
Rating power(KW) | 8 | 16 | 24 | 32 | 40 | 48 | 64 | 80 | 96 | 120 | 160 | 200 | 240 | 320 |
|
|
Phases | Tri-phasic (Line)+N |
Input volt. | 380VAC±1%(stable load),380VAC±5%(fluctuated load) |
Input frequency | 50Hz ± 0.05% (Battery status) |
Stable-freq: | <±0.05% |
Non-synchronization |
Stable-freq: Synchronization | <±2% |
Crestor factor | 51 |
Output waveform | Pure sine wave output |
THD | <3% when linear load status; <5% when non-linear load |
Dynamic voltage range when UPS loaded(0-100%)) | <±5% |
Instance recover time | <10ms |
Three-phases output volt. Non-balance | balance load volt.<±1%; |
1\50% non-balance volt.<±3%; |
2\100% non-balance load<±5% |
Three phase output-volt. Tolerance | Balance load:±1°; |
Non-balance load:±3° |
Over-load capacity | 125% 10min,150% 1min |
Inverter efficiency when 100% load | 91 | 92 | 92 | 93 | 93 | 93 | 95 | 95 | 95 | 95 | 95 | 95 | 95 | 95 |
Bypass |
Phases | Tri-phasic(Line)+N |
Input voltage | 380VAC±15% |
Input frequency | 50Hz(60Hz)±5% |
Transfer time | 0ms from Inverter to bypass when overload status |
System |
MTBF | 300,000 Hrs |
MTTR | 2Hrs (counted on spot) |
Grounding resistor | ≤1Ω |
Grounding mode | TN-S grounding |
Efficiency (100% load status) | >80% |
Computer communication interface | RS232 |
Operating temperature | 0~40°C |
Relative humidity | 30%~90% (non-condense) |
Performance maximum height) | <1000 M(Max:4000M, height more 100, power lower 1% |
Hot sink | Obliged air-floating |
Noise(Distance away from ups1M) | 48~58dB | 50~62dB | 52~65dB |
Case color | Grey |
Input cable | UPS below or UPS back panel |
Maintain easily | Open to front/back panel, as well as left and right side |
Input device | Terminators |
Output device | Terminators |
Model(KVA) | 10KL | 20KL | 30KL | 40KL | 50KL | 60KL | 80KL | 100KL | 120KL | 150KL | 200KL | 250KL | 300KL | 400KL |
Dimension ( L×W × H ) | 600×800×1500 | 600×800×1700 | 1000×1000×1800 | 1200×1000×1800 | 1300×1400×2000 |
|
N.W ( KG ) | 320 | 360 | 450 | 500 | 540 | 600 | 800 | 900 | 950 | 1100 | 1250 | 1350 | 1800 | 2000 |
|
Address:
The 5th Floor, C1 Building, New Lighting Industry Base, Nanhai Dist, Foshan, Guangdong, China
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics, Industrial Equipment & Components, Instruments & Meters, Light Industry & Daily Use, Lights & Lighting, Manufacturing & Processing Machinery, Metallurgy, Mineral & Energy, Tools & Hardware, Toys, Transportation
Management System Certification:
ISO 9001
Company Introduction:
Foshan Polytex Technology Co., Ltd. Was founded in 2009, which is located at Guangdong New Lighting Industrial Base, Nanhai District, Foshan City, Guangdong Province of China, specialize in Renewable Energy, include Uninterruptible Power Supply ( UPS ), High Frequency Online UPS, offline UPS, home UPS, normal frequency online UPS, inverter, include off-grid inverter and on-grid inverter for solar system and wind turbine system, Telocom Inverter, Battery, include lead acide battery, deep cycle battery, GEL battery, Solar and Wind turbine Hybrid system, include solar charge controller, solar panels and small wind turbine system and LED street lights.
Foshan Polytex Technology Co., Ltd has a strong team consisted of highly competent personnel for the R&D, sales and production. Besides, the company applies the advanced production technology and the impeccable detection, measuring and testing quality control equipment. With the accurate measuring & testing technology as well as the perfect ISO9001: 2008 quality management system, the company insists on pursuing the products′ Reliability, practicality and advanced nature as well as continuously seeking for the technical breakthrough and innovation which bring the brand new conception of the product development for us. Currently, our products have passed through such related certifications as CE/EMC, RoHS, TLC, UL and TLC.
Foshan Polytex Technology Co., Ltd adheres to the "people-oriented, pragmatic, dynamic, creative excellence" enterprise culture. In order to provide the high-quality, reliable, energy-saving and environmentally green products to the society, we take soft cultural marketing to display our hard power while focusing on the combination of the company′ S inner management and external development.
Foshan Polytex Technology Co., Ltd is willing to work with all domestic and overseas friends from various kinds of fields and create our brilliant future together.